  高壓變壓器的保(bao)護配置(zhi)如何實施到(dao)位(wei)?

  1、裝設避(bi)雷(lei)(lei)(lei)器保(bao)護,防止雷(lei)(lei)(lei)擊(ji)過電壓:配變(bian)的防雷(lei)(lei)(lei)保(bao)護,采用(yong)裝設無間隙(xi)金屬氧(yang)化物避(bi)雷(lei)(lei)(lei)器作為過電壓保(bao)護,以(yi)防止由高(gao)低壓線路侵(qin)入的高(gao)壓雷(lei)(lei)(lei)電波所(suo)引起(qi)的變(bian)壓器內部(bu)絕(jue)緣(yuan)擊(ji)穿,造成短路,杜絕(jue)發生雷(lei)(lei)(lei)擊(ji)破(po)壞(huai)事故。

  采(cai)用避雷器保護(hu)配變時(shi),一是(shi)(shi)要通過正常渠道采(cai)購合(he)格(ge)產品(pin)(pin),安裝投運(yun)前經(jing)過嚴(yan)格(ge)的(de)試(shi)驗(yan)達到運(yun)行(xing)要求(qiu)再投運(yun);二是(shi)(shi)對運(yun)行(xing)中的(de)設(she)備定(ding)期(qi)進行(xing)預防性試(shi)驗(yan),對于泄漏(lou)電(dian)流值超(chao)過標準值的(de)不合(he)格(ge)產品(pin)(pin)及時(shi)加以更換;三是(shi)(shi)定(ding)期(qi)進行(xing)變壓器接(jie)地(di)(di)電(dian)阻檢測,對100KVA及以上的(de)配電(dian)變壓器要求(qiu)接(jie)地(di)(di)電(dian)阻必須在4Ω以內,對100KVA以下(xia)的(de)配電(dian)變壓器,要求(qiu)接(jie)地(di)(di)電(dian)阻必須在10Ω以內。

  如果(guo)測試值不在(zai)規定(ding)范圍(wei)內(nei),應(ying)采取(qu)延伸接(jie)(jie)(jie)(jie)地(di)線,增加接(jie)(jie)(jie)(jie)地(di)體及物理(li)、化學等(deng)措施使其(qi)達(da)到規定(ding)值,每年的(de)(de)4月份(fen)和(he)7月份(fen)進(jin)行(xing)兩次接(jie)(jie)(jie)(jie)地(di)電(dian)(dian)阻的(de)(de)復測,防止焊接(jie)(jie)(jie)(jie)點(dian)脫焊、環境及其(qi)它(ta)因(yin)素導致接(jie)(jie)(jie)(jie)地(di)電(dian)(dian)阻超(chao)標。如果(guo)變(bian)(bian)壓(ya)(ya)器接(jie)(jie)(jie)(jie)地(di)電(dian)(dian)阻超(chao)標,雷(lei)(lei)(lei)擊時雷(lei)(lei)(lei)電(dian)(dian)流不能流入大地(di),反而通過接(jie)(jie)(jie)(jie)地(di)線將雷(lei)(lei)(lei)電(dian)(dian)壓(ya)(ya)加在(zai)配(pei)電(dian)(dian)變(bian)(bian)壓(ya)(ya)器低壓(ya)(ya)側再反向(xiang)升壓(ya)(ya)為高電(dian)(dian)壓(ya)(ya),將配(pei)變(bian)(bian)燒毀;四是安裝位置選擇應(ying)適(shi)當(dang),高壓(ya)(ya)避雷(lei)(lei)(lei)器安裝在(zai)靠配(pei)變(bian)(bian)高壓(ya)(ya)套管近的(de)(de)引線處,盡量減小雷(lei)(lei)(lei)電(dian)(dian)直接(jie)(jie)(jie)(jie)侵入配(pei)變(bian)(bian)的(de)(de)機(ji)會,低壓(ya)(ya)避雷(lei)(lei)(lei)器裝在(zai)靠配(pei)變(bian)(bian)近的(de)(de)低壓(ya)(ya)套管處,以保證雷(lei)(lei)(lei)電(dian)(dian)波(bo)侵入配(pei)變(bian)(bian)前的(de)(de)正確動作,按電(dian)(dian)氣設(she)備安裝規范標準要(yao)求(qiu)安裝,防止盲目安裝而失(shi)去保護的(de)(de)意義。

  2、裝(zhuang)設(she)速斷、過(guo)電(dian)流(liu)保(bao)(bao)護(hu)(hu),保(bao)(bao)證有選(xuan)擇性地切除故障線(xian)路:配(pei)(pei)變(bian)(bian)的短路保(bao)(bao)護(hu)(hu)和過(guo)載(zai)保(bao)(bao)護(hu)(hu)由裝(zhuang)設(she)于(yu)配(pei)(pei)變(bian)(bian)高(gao)壓側的熔(rong)斷器(qi)(qi)和低(di)(di)壓側的漏電(dian)總保(bao)(bao)護(hu)(hu)器(qi)(qi)(該(gai)裝(zhuang)置有漏電(dian)保(bao)(bao)護(hu)(hu)和配(pei)(pei)變(bian)(bian)低(di)(di)壓過(guo)電(dian)流(liu)保(bao)(bao)護(hu)(hu))來實現。為了有效地保(bao)(bao)護(hu)(hu)配(pei)(pei)變(bian)(bian),必須正確選(xuan)擇熔(rong)斷器(qi)(qi)的熔(rong)體(ti)(熔(rong)絲、熔(rong)片等)及低(di)(di)壓過(guo)電(dian)流(liu)保(bao)(bao)護(hu)(hu)定(ding)值。高(gao)壓側熔(rong)絲的選(xuan)擇,應能保(bao)(bao)證在(zai)變(bian)(bian)壓器(qi)(qi)內部或外部套管處發生短路時被熔(rong)斷。熔(rong)絲選(xuan)擇原(yuan)則(ze):(1)容量(liang)在(zai)100kVA及以(yi)下的配(pei)(pei)變(bian)(bian),高(gao)壓熔(rong)絲按2~2.5倍(bei)額定(ding)電(dian)流(liu)選(xuan)擇;(2)容量(liang)在(zai)100kVA以(yi)上(shang)的配(pei)(pei)變(bian)(bian),高(gao)壓熔(rong)絲按1.5~2倍(bei)額定(ding)電(dian)流(liu)選(xuan)擇。

  低(di)壓(ya)(ya)側漏電總保(bao)(bao)護器過(guo)流(liu)(liu)動(dong)作(zuo)值(zhi)取配(pei)(pei)變(bian)低(di)壓(ya)(ya)側額定(ding)值(zhi)的1.3倍(bei),配(pei)(pei)變(bian)低(di)壓(ya)(ya)各分支線(xian)(xian)路過(guo)流(liu)(liu)保(bao)(bao)護定(ding)值(zhi)不應大于總保(bao)(bao)護的過(guo)流(liu)(liu)動(dong)作(zuo)值(zhi),其值(zhi)應小(xiao)于配(pei)(pei)變(bian)低(di)壓(ya)(ya)側額定(ding)電流(liu)(liu),一般按導(dao)線(xian)(xian)載流(liu)(liu)量選(xuan)擇過(guo)流(liu)(liu)值(zhi),保(bao)(bao)證在各出線(xian)(xian)回路發(fa)生短(duan)路或輸出負載過(guo)大,引起配(pei)(pei)變(bian)過(guo)負荷時能及時動(dong)作(zuo),切(qie)除負載和(he)故(gu)障線(xian)(xian)路,實現保(bao)(bao)護配(pei)(pei)變(bian)的目的。

  同時(shi)滿足各級保(bao)(bao)(bao)(bao)護(hu)的選擇性(xing)要求。低(di)壓(ya)分支回(hui)路(lu)(lu)(lu)短路(lu)(lu)(lu)故障時(shi),分支回(hui)路(lu)(lu)(lu)動作,漏(lou)電(dian)總(zong)保(bao)(bao)(bao)(bao)護(hu)器(qi)過(guo)流保(bao)(bao)(bao)(bao)護(hu)不動作,低(di)壓(ya)側總(zong)回(hui)路(lu)(lu)(lu)故障或短路(lu)(lu)(lu)時(shi),低(di)壓(ya)側漏(lou)電(dian)總(zong)保(bao)(bao)(bao)(bao)護(hu)器(qi)過(guo)流保(bao)(bao)(bao)(bao)護(hu)動作,高壓(ya)側熔(rong)(rong)體(ti)(ti)不應熔(rong)(rong)斷(duan);變壓(ya)器(qi)內部故障短路(lu)(lu)(lu)時(shi),高壓(ya)側熔(rong)(rong)體(ti)(ti)熔(rong)(rong)斷(duan),上一級變電(dian)站高壓(ya)線(xian)路(lu)(lu)(lu)保(bao)(bao)(bao)(bao)護(hu)裝置不應動作跳閘,保(bao)(bao)(bao)(bao)證(zheng)配(pei)電(dian)網保(bao)(bao)(bao)(bao)護(hu)裝置正確分級動作。配(pei)變高壓(ya)側熔(rong)(rong)體(ti)(ti)保(bao)(bao)(bao)(bao)護(hu)材料一定要按標準配(pei)備,堅決杜絕用銅、鋁等金屬導體(ti)(ti)替代熔(rong)(rong)斷(duan)器(qi)熔(rong)(rong)體(ti)(ti)。